A centrifugal pump that needs refilling after every shutdown may be losing liquid from its casing or suction pipe. Stop repeated dry starts. Check the suction arrangement against the exact pump manual before ordering a replacement.

Separate loss of prime from low inlet pressure

Record whether the casing is full before start-up, the source liquid level, suction gauge reading and any air seen during a controlled start. A flooded-suction installation and a suction-lift installation have different checks. If liquid stays in the casing but flow is poor, investigate inlet pressure, blockage and the operating point instead of assuming a failed foot valve.

Observation First check
Casing empties while stopped Suction joints, drain points and foot valve if fitted
Casing remains full but flow is low Inlet restriction, air entry and pump duty

Inspect the suction path safely

Isolate electrical power and release pressure before opening the system. Check pipe joints, gaskets, priming plugs and the suction strainer for leaks or obstruction. Where a foot valve is fitted, inspect its seat and movement for debris or wear. Confirm that the source level does not uncover the intake. Refill and vent only by the procedure for that pump; never use repeated dry runs as a test.

Prepare a repair or replacement enquiry

Send the pump nameplate, suction layout, liquid level range, valve details, photos and observations before and after shutdown. State whether the problem began after maintenance or a piping change. Ask for a compatible valve, seal or pump review only after the failed path is identified; dimensions and materials depend on the exact installation.

pump products; selection and service support; request a quotation.

  1. Record the casing level before starting and after stopping.
  2. Inspect suction joints and any fitted foot valve with the system isolated.
  3. Refill, vent and restart according to the specific manual.

Frequently asked questions

Does every centrifugal pump need a foot valve?

No. A foot valve may help a suction-lift line retain liquid; a flooded-suction arrangement is different. Follow the approved layout and pump manual.

Can an air leak occur without visible water leakage?

Yes. A suction line below atmospheric pressure can draw in air at a joint without leaving an obvious wet mark when the pump runs.